Pàgina inicial > Articles > Articles publicats > Using Single-Voxel Magnetic Resonance Spectroscopy Data Acquired at 1.5T to Classify Multivoxel Data at 3T : |
Data: | 2023 |
Resum: | In vivo magnetic resonance spectroscopy (MRS) has two modalities, single-voxel (SV) and multivoxel (MV), in which one or more contiguous grids of SVs are acquired. Purpose: To test whether MV grids can be classified with models trained with SV. Methods: Retrospective study. Training dataset: Multicenter multiformat SV INTERPRET, 1. 5T. Testing dataset: MV eTumour, 3T. Two classification tasks were completed: 3-class (meningioma vs. aggressive vs. normal) and 4-class (meningioma vs. low-grade glioma vs. aggressive vs. normal). Five different methods were tested for feature selection. The classification was implemented using linear discriminant analysis (LDA), random forest, and support vector machines. The evaluation was completed with balanced error rate (BER) and area under the curve (AUC) on both sets. The accuracy in class prediction was calculated by developing a solid tumor index (STI) and segmentation accuracy with the Dice score. Results: The best method was sequential forward feature selection combined with LDA, with AUCs = 0. 95 (meningioma), 0. 89 (aggressive), 0. 82 (low-grade glioma), and 0. 82 (normal). STI was 66% (4-class task) and 71% (3-class task) because two cases failed completely and two more had suboptimal STI as defined by us. Discussion: The reasons for failure in the classification of the MV test set were related to the presence of artifacts. |
Ajuts: | European Commission 813120 Instituto de Salud Carlos III PI20/00064 Instituto de Salud Carlos III PI20/00360 Ministerio de Economía y Competitividad SAF2014-52332-R Ministerio de Sanidad y Consumo CB06/01/0010 Agencia Estatal de Investigación PID2019-104551RB-I00 |
Drets: | Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. |
Llengua: | Anglès |
Document: | Article ; recerca ; Versió publicada |
Matèria: | Magnetic resonance spectroscopy ; Brain tumors ; Glioblastoma multiforme ; Decision support systems ; Nosologic imaging ; Metabolic pattern |
Publicat a: | Cancers, Vol. 15, Issue 14 (July 2023) , art. 3709, ISSN 2072-6694 |